VERSATILE EVALUATION OF EFFECTS ON DCT-BASED LOSSY COMPRESSION OF EMG SIGNALS ON MEDICAL PARAMETERS

Tiia Siiskonen, Tapio Grönfors, Niina Päivinen

2007

Abstract

Typically used simplified error measures, like mean-squared-error (MSE), do not reveal everything about the clinical quality of lossy compressed medical signals. Errors have to be interpreted via essential medical parameters. The medical parameters depend on the type of the signal and only the preservation of essential medical parameters can guarantee the correct clinical quality. In this study, short electromyography (EMG) signals are compressed with DCT transformation -based lossy compression method. The compression is gained with irreversible masking and scalar quantization of the DCT coefficients. The most prominent medical parameters of EMG signal are the mean frequency (MNF) and the median frequency (MDF). The behaviors of these parameters are studied both by fitting a regression line and by examining the mean absolute errors frequency-by-frequency over clinically interesting frequency range. This reveals the frequency dependency of errors of the medical parameters and inspires the idea that the generated linear model can be used for estimating the correct value of the processed medical parameter.

Download


Paper Citation


in Harvard Style

Siiskonen T., Grönfors T. and Päivinen N. (2007). VERSATILE EVALUATION OF EFFECTS ON DCT-BASED LOSSY COMPRESSION OF EMG SIGNALS ON MEDICAL PARAMETERS . In Proceedings of the Fourth International Conference on Informatics in Control, Automation and Robotics - Volume 3: ICINCO, ISBN 978-972-8865-84-9, pages 149-156. DOI: 10.5220/0001640501490156

in Bibtex Style

@conference{icinco07,
author={Tiia Siiskonen and Tapio Grönfors and Niina Päivinen},
title={VERSATILE EVALUATION OF EFFECTS ON DCT-BASED LOSSY COMPRESSION OF EMG SIGNALS ON MEDICAL PARAMETERS},
booktitle={Proceedings of the Fourth International Conference on Informatics in Control, Automation and Robotics - Volume 3: ICINCO,},
year={2007},
pages={149-156},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001640501490156},
isbn={978-972-8865-84-9},
}


in EndNote Style

TY - CONF
JO - Proceedings of the Fourth International Conference on Informatics in Control, Automation and Robotics - Volume 3: ICINCO,
TI - VERSATILE EVALUATION OF EFFECTS ON DCT-BASED LOSSY COMPRESSION OF EMG SIGNALS ON MEDICAL PARAMETERS
SN - 978-972-8865-84-9
AU - Siiskonen T.
AU - Grönfors T.
AU - Päivinen N.
PY - 2007
SP - 149
EP - 156
DO - 10.5220/0001640501490156