Beat-by-Beat Monitoring of Systolic Blood Pressure based on an ASIC and a Mobile Phone for Ambulatory Application

Wenxi Chen, Ming Huang, Xin Zhu, Kei-ichiro Kitamura, Tetsu Nemoto

2013

Abstract

This paper describes an ambulatory monitor for beat-by-beat monitoring of systolic blood pressure (SBP) based on an ASIC chip and a mobile phone. The ASIC is able to measure electrocardiogram (ECG), photoelectric plethysmogram (PPG), and has a peripheral interface to control an air pump and valve for inflating and deflating a sphygmomanometer cuff in conventional blood pressure measurement. Algorithms for signal processing, characteristic point detection and SBP estimation are implemented on a mobile phone. Pulse arrival time (PAT) is derived from the apex of QRS complex to the maximum slope of PPG, and is used to estimate a rapid change component in SBP beat-by-beat. An oscillometric sphygmomanometer with a cuff is used to determine SBP intermittently for calibration purpose. Data communication between a mobile phone and the ambulatory monitor is conducted via a Bluetooth wireless connection. Performance of the prototype is examined by data from five healthy college students. The results show that 65.9% of estimated SBP fall into ±5% relative error, 96.6% in ±10% and 99.7% in ±15%. This prototype is a pilot study aiming at integrating an innovative sphygmomanometry into a mobile phone for continuous blood pressure monitoring. We expect to find potential applications in ambulatory monitoring and daily healthcare.

Download


Paper Citation


in Harvard Style

Chen W., Huang M., Zhu X., Kitamura K. and Nemoto T. (2013). Beat-by-Beat Monitoring of Systolic Blood Pressure based on an ASIC and a Mobile Phone for Ambulatory Application . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2013) ISBN 978-989-8565-34-1, pages 10-13. DOI: 10.5220/0004192600100013

in Bibtex Style

@conference{biodevices13,
author={Wenxi Chen and Ming Huang and Xin Zhu and Kei-ichiro Kitamura and Tetsu Nemoto},
title={Beat-by-Beat Monitoring of Systolic Blood Pressure based on an ASIC and a Mobile Phone for Ambulatory Application},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2013)},
year={2013},
pages={10-13},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004192600100013},
isbn={978-989-8565-34-1},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2013)
TI - Beat-by-Beat Monitoring of Systolic Blood Pressure based on an ASIC and a Mobile Phone for Ambulatory Application
SN - 978-989-8565-34-1
AU - Chen W.
AU - Huang M.
AU - Zhu X.
AU - Kitamura K.
AU - Nemoto T.
PY - 2013
SP - 10
EP - 13
DO - 10.5220/0004192600100013