Medical image diagnosis processes with stereoscopic depth by 3D display have not been developed widely yet and remain understudied Many stereoscopic displays require glasses that are inappropriate for use in clinical diagnosis/explanation/operating processes in hospitals. An eye-tracking based glasses-free three-dimensional autostereoscopic display monitor system has been developed, and its feasibility for medical 3D images was investigated, as a cardiac CT 3D navigator. Our autostereoscopic system uses slit-barrier with BLU, and it is combined with our vision-based eye tracking system to display 3D images. Dynamic light field rendering technique is applied with the 3D coordinates calculated by the eye-tracker, in order to provide a single viewer the best 3D images with less x-talk. To investigate the feasibility of our autostereoscopic system, 3D volume was rendered from 3D coronary CTA images (512 by 512 by 400). One expert reader identified the three main artery structures (LAD, LCX and RCA) in shorter time than existing 2D display. The reader did not report any eye fatigue or discomfort. In conclusion, we proposed a 3D cardiac CT navigator system with a new glasses-free 3D autostereoscopy, which may improve diagnosis accuracy and fasten diagnosis process.

Download


Paper Citation


in Harvard Style

Kang D., Lee S., Hwang H., Park J., Heo J., Kang B., Lee J., Choi Y., Choi K. and Nam D. (2016). Feasibility of Eye-tracking based Glasses-free 3D Autostereoscopic Display Systems for Medical 3D Images . In Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 2: BIOIMAGING, (BIOSTEC 2016) ISBN 978-989-758-170-0, pages 134-138. DOI: 10.5220/0005826901340138

in Bibtex Style

@conference{bioimaging16,
author={Dongwoo Kang and Seok Lee and Hyoseok Hwang and Juyong Park and Jingu Heo and Byongmin Kang and Jin-Ho Lee and Yoonsun Choi and Kyuhwan Choi and Dongkyung Nam},
title={Feasibility of Eye-tracking based Glasses-free 3D Autostereoscopic Display Systems for Medical 3D Images},
booktitle={Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 2: BIOIMAGING, (BIOSTEC 2016)},
year={2016},
pages={134-138},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005826901340138},
isbn={978-989-758-170-0},
}


in EndNote Style

TY - CONF
JO - Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 2: BIOIMAGING, (BIOSTEC 2016)
TI - Feasibility of Eye-tracking based Glasses-free 3D Autostereoscopic Display Systems for Medical 3D Images
SN - 978-989-758-170-0
AU - Kang D.
AU - Lee S.
AU - Hwang H.
AU - Park J.
AU - Heo J.
AU - Kang B.
AU - Lee J.
AU - Choi Y.
AU - Choi K.
AU - Nam D.
PY - 2016
SP - 134
EP - 138
DO - 10.5220/0005826901340138