LOW-INVASIVE HEATING AND TEMPERATURE MEASUREMENT METHOD FOR HYPERTHERMIA TREATMENT USING THE METAL COATED FERROMAGNETIC IMPLANT WITH LOW CURIE TEMPERATURE

Kazutaka Mitobe, Noboru Yoshimura

2011

Abstract

Hyperthermia has been used for many years to treat various types of malignant tumor because tumor cells are more sensitive to temperature in the range of 42-45°C than are normal tissue cells. In this study, we aim to develop the local heating method and monitoring method for hyperthermia using the Ferromagnetic Implant with Low Curie Temperature (FILCT) under high frequency magnetic field. The heat generation inefficiency of FILCT causes a barrier in order to use this method as a bedside tool. In this research work, we coated the FILCT with a metal material in order to improve the heat generation efficiency. The magnetic permeability of FILCT decreased around the Curie temperature; therefore we can use FILCT as a thermal probe by measuring of the changing vector of the magnetic flux at the outside of human body noninvasively. In this paper, we describe about the experimental setup and in vitro experimental results.

Download


Paper Citation


in Harvard Style

Mitobe K. and Yoshimura N. (2011). LOW-INVASIVE HEATING AND TEMPERATURE MEASUREMENT METHOD FOR HYPERTHERMIA TREATMENT USING THE METAL COATED FERROMAGNETIC IMPLANT WITH LOW CURIE TEMPERATURE . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011) ISBN 978-989-8425-37-9, pages 341-344. DOI: 10.5220/0003152803410344

in Bibtex Style

@conference{biodevices11,
author={Kazutaka Mitobe and Noboru Yoshimura},
title={LOW-INVASIVE HEATING AND TEMPERATURE MEASUREMENT METHOD FOR HYPERTHERMIA TREATMENT USING THE METAL COATED FERROMAGNETIC IMPLANT WITH LOW CURIE TEMPERATURE},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)},
year={2011},
pages={341-344},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003152803410344},
isbn={978-989-8425-37-9},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)
TI - LOW-INVASIVE HEATING AND TEMPERATURE MEASUREMENT METHOD FOR HYPERTHERMIA TREATMENT USING THE METAL COATED FERROMAGNETIC IMPLANT WITH LOW CURIE TEMPERATURE
SN - 978-989-8425-37-9
AU - Mitobe K.
AU - Yoshimura N.
PY - 2011
SP - 341
EP - 344
DO - 10.5220/0003152803410344